-40%
TTC Fireberd 4000 digital comunications analyzer
$ 10.56
- Description
- Size Guide
Description
Powers up switches and clock works but I have no way to test any of it's functions.It was last calibrated on 5/4/05 according to the service sticker on top.This is the second of 2 of these I have.USA shipping only.No returns unless damaged in shipping.You have 3 days to contact me for a refund.
Operates at rates of 50b/s to 15MB/s for testing digital communications circuits
The JDSU/Acterna/TTC Fireberd 4000 will simultaneously measure bit errors, code violations, frame errors, block errors, pattern slips, and performs signal analysis. RS-232 and MIL-188-114 interfaces are standard.
Description
The FIREBERD 4000 Communications Analyzer is a flexible, cost-effective instrument that tests digital circuits and equipment. Combining convenience and reliable performance, the FIREBERD 4000 is ideally suited for a wide variety of test applications.
Operating at rates from 50 b/s to 15 Mb/s, the FIREBERD 4000 provides a high degree of flexibility for testing G.703, T-Carrier, and DDS circuits, evaluating equipment performance, or performing long-term or unattended testing. THe instrument features a range of standard data rates, plus the ability to operate at non-standard data rates when the optional frequency synthesize is installed.
Specifications
Operating Ranges
Synchronous:
50 b/s to 15 Mb/s.
Asynchronous:
50 b/s to 20 kb/s (Internal RS-232/V.24 and MIL-188C interfaces only).
Generator Timing
Clock Sources:
Fixed internal frequencies, data interface and external BNC.
Internal Clock Frequencies:
300 Hz, 1.2 kHz, 2.4 kHz, 4.8 kHz, 9.6 kHz, 19.2 kHz, 56 kHz, 64 kHz, 128 kHz, 256 kHz, 512 kHz, 1544 kHz, and 2048 kHz +/- 5ppm.
Data Generator
Fixed Patterns:
Mar, Space, 1:1, 1:7, 3-in-24, and a user-programmable pattern of 3 to 24 bits in length.
Pseudorandom Patterns:
63, 511, 2047, 2
15-1
, 2
20-1
, 2
23-1
, QRSS.
Messages:
Non Programmable: standard FOX asynchronous message in four different code levels; Programmable: three asynchronous messages up to 2000 bytes in length.
Asynchronous Setup:
Odd, none, or even parity; 5- to 8-bit code levels; 1, 1.5, or 2 stop bits.
Error Insertion:
Single error or fixed 10
-3
rate in generated data only.
Error Analysis Receiver
Sync Loss Thresholds:
User-Selectable 100/21, 250/21, and 20,000/100,000 errors/total bits.
Block Lengths:
10
2
to 10
6
bits, or pattern lengths.
Signal Analysis
Frequency Measurement Range:
50 Hz to 16 MHz.
Accuracy:
+/- 5ppm
Test Results
Summary Results (Non-Zero results only):
Bit errors, bipolar violations (BPVs), character errors, code errors, cylic redundancy check (CRC) errors, block errors, frame errors, frame alignmen signal (FAS) errors, pattern slips, pattern loss.
Error Results:
Average bit error rate, average block error rate, bit errors, bit error rate, blocks, block errors, character errors, pattern loss, pattern slips.