-40%
Ixia Keysight XGS12-HS XM100GE4CXP+FAN (100/40/10GE) 4x100G Layer 2-7 testing
$ 30093.35
- Description
- Size Guide
Description
This unit arrives tested working with a 1 year hardware warranty. I will ship nearly anywhere in the world on our account if you submit a full price offer.1x
Ixia
XGS12-HS
- 12-SLOT CHASSIS BUNDLE with XGS12 rack mountable chassis and High Performance Controller Module. The XGS12-HS bundle supports both IxLoad and BreakingPoint software applications.
The chassis includes the following:
* Chassis frame assembly, w/ STD SYNC (941-0041)
* High Performance Processor Module (942-0048)
* Fan assembly module (942-0031)
* 6000W power supply module (942-0032)
XGS12 12-slot modular chassis platform
delivers the most comprehensive solution for
performance, functional, security, and conformance
testing of network equipment and network applications
at scale. Operating in conjunction with Keysight’s
industry-leading IxNetwork, IxLoad, and BreakingPointi
test applications and automation APIs, this platform
provides the power and performance necessary for
massive-scale Layer 2-7 testing.
1x
Ixia XM100GE4CXP+FAN (100/40/10GE)
-
1-slot / 4x100GE and 12x40GE ports
10GE fan-out (944-1101)
• 1-slot / 12x10GE (3x10GE/port) • 1-slot / 32x10GE (8x10GE/port)
•
1-slot / 32x10GE (8x10GE/port)
944-1101
Xcellon-Multis XM100GE4CXP+FAN 100/40-Gigabit Ethernet, multiple rate load module, 1-slot with 4-ports of
native 100GE CXP multimode interfaces and up to 12-ports of 40GE via fan-out cables with L2-7 support. The
load module is compatible with the XGS2-SD 2-slot, 3RU standard performance rack-mountable chassis
bundle (940-0010), XGS12-SD 12-slot, 11RU standard performance rack-mountable chassis bundle (940-
0011), XGS2-SDL 2-slot, 3RU standard performance rack-mountable chassis bundle (940-0013), XGS12-SDL
12-slot, 11RU standard performance rack-mountable chassis bundle (940-0015), XGS2-HSL 2-slot, 3RU high
performance rack-mountable chassis bundle (940-0014), and XGS12-HSL 12-slot, 11RU high performance
rack-mountable chassis bundle (940-0016).
REQUIRES one or more per port of the following 100GE media: CXP 100GE pluggable, multimode optical
transceiver (948-0030) and MTP-MTP 24-fiber, multimode point-to-point 100GE cable, 3-meter (942-0035), or
point-to-point, multimode CXP 100GE Active Optical Cable (AOC), 3-meter [942-0052]. Also requires one or
more per port of the following 40GE media: MTP-to-MTP passive fiber for 3x40GE fan-out, 3-meter (942-0060),
5-meter (942-0061); these cables may be used with QSFP 40GBASE-SR4 transceivers (948-0031).
The XGS12 chassis specifications are contained in the following tables.
Table 7-3. XGS12-HS Processor Module Specifications:
Processor Module
Field replaceable and removable processor card module with 2 x INTEL Sandy Bridge EP, E5-2658 2.1 GHz processors
Memory
64 GB RAM
Hard Disk Drive
Dual 400 GB Solid-State Drives
Operating System
Native Linux OS and Win7 VM for IxOS
Other Specs
IPMI support
Table 7-4. XGS12-Standard Processor Module Specifications:
Processor Module
Field replaceable and removable processor card module with an Intel 2.26 GHz Core™ 2 Duo processor with 4 GB CPU memory, and 250 GB SATA hard drive
Memory
4GB
Hard Disk Drive
250GB
Operating System
Windows 7
Caution–Battery replacement
There is danger of explosion if battery is incorrectly replaced. Do not attempt to replace the battery.
Return to Ixia Customer Service for replacement with the same or equivalent type of battery. Ixia disposes of used batteries according to the battery manufacturer's instructions.
Note
: The serial number for the Processor Module is located on module itself. This is used as the overall chassis serial number.
Table 7-5. XGS12 Chassis Specifications:
Size
19.0 in. W x 19.21 in. H x 27.2 in. D
48.26cm W x 48.79cm H x 69.09cm D
11 rackmount units (11RU)
Load Module Slots
12 (compatible with Ixia XM form factor load modules)
Chassis Power
The chassis requires three single phase, 200-240VAC, 50/60Hz circuits, each capable of providing 3680 watts. These circuits must provide protection against over-currents, short circuits and earth faults for the XGS12 chassis. A 20A circuit breaker for each circuit is also required.
All three power cords must be plugged into their single phase 200-240VAC, 50Hz/60Hz power sources at the same time for correct operation of the chassis.
Note
: The chassis power supplies are interlocked with the rear cover which must be installed for them to be enabled. After removing or installing the rear panel, ensure thumbscrews have been tightened down with a 'Flat Blade' screwdriver.
Note
: The load module power is enabled by the Ixia server program. If it is not running, the load modules will not be powered on.
Power Cords
All three power cords are required to operate the XGS12 chassis power supplies.
Power Cord shipments:
Ixia provides three power cords that are configured and rated to meet the specifications of the target country where the chassis is being installed.
For North American customers, the power cords have NEMA L6-20P plugs for attachment to the power source and IEC-60320-C19 connectors that attach to the XGS12 chassis.
For International shipments, the power cords supplied has plugs suitable for each destination country's power source and IEC-60320-C19 connectors that attach to the XGS12 chassis.
Chassis Weights
Frame
:
64 lbs. (29.1 kg) empty, component weight
97 lbs. (44.1 kg) average shipping weight (with filler panels)
Fan module
:
10.2 lbs. (4.63 kg) component weight
17.3 lbs. (7.86 kg) average shipping weight
Power Supply module
:
28 lbs. (12.72 kg) component weight
35.1 lbs. (15.95 kg) average shipping weight
Processor module (Standard)
:
2.7 lbs. (1.23 kg) component weight
8.5 lbs. (3.86 kg) average shipping weight
Processor module (High Performance
10 lbs. (4.54 kg) component weight
15.8 lbs. (7.17 kg) average shipping weight
Warning
: Total chassis weight, without any load modules installed is 112.2 lbs. (50.89 kg). Do not attempt to lift the fully assembled chassis.
Fan Module
Field replaceable chassis fan assembly that is easily installed and removed.
Air flow Clearance
12 inches is required at the rear of the chassis.
24 inches of clearance is preferred.
Power Supply Module
Field replaceable power supply module that is easily installed and removed.
There are three 2825W power supplies in the Power Supply Module.
Each power supply may be removed or replaced separately.
Timing Sources
Internal clock, synchronized with another Ixia chassis, GPS AFD-1unit, AFD2 IRIG-B unit or with the Timing Distribution Module.
Shipping Vibration
FED-STD-101C, Method 5019.1/5020.1
Operating temperature
41×F to 104×F, (5×C to 40×C)
Note
: Some high-density/high performance load modules require a lower maximum ambient operating temperature than the standard for the chassis. When a load module that requires the lower maximum operating temperature is installed in an XM chassis, the maximum operating temperature of the chassis is adjusted downward to match the maximum operating temperature of the load module. The operating temperature range specification is specified in the published datasheet for these load modules.
Storage temperature
41
o
F to 122
o
F, (5
o
C to 50
o
C)
Operating Humidity
0% to 85%, non-condensing
Storage Humidity
0% to 85%, non-condensing
Noise
The XGS12 chassis running at maximum fan speed capacity may produce noise levels up to 87 dB(A). This is measured per the GR-63-CORE, Issue 1, paragraph 5.6.3 specification. The use of appropriate ear protection is recommended to protect against hearing impairment. Consult local health and safety regulations for recommended maximum exposure levels for noise and ear protection devices.
Shown below are the maximum XGS12 chassis sound levels measured according to GR-63-CORE, Issue 1, Paragraph 5.6.3.
Front: 83.5 dB(A)
Left Side: 84.2 dB(A)
Rear: 86.5 dB(A)
Right Side: 84.4 dB(A)